Industrial

We are recognised as a leading electrical contracting company. Our success is built upon an unwavering dedication to providing high quality, reliable and cost effective solutions.

Industrial Services

  1. OEM trained by CAT/Bucyrus/Komatsu
  2. Over 14 years of experience guiding personnel on the understanding of Bucyrus and CAT electrical systems
  3. Extensive training on troubleshooting and diagnosing SIEMENS drives
  4. Comprehensive knowledge of SIEMENS STEP 7 PLC systems 
  5. Trained in the operation of industrial data acquisition tooling 
  6. 14 years of experience repairing and replacing electrical drive components

Motor Services

lighting installations services
  1. Inspect motor components, including bearings, shafts, and belts, for signs of wear or damage. Replace any worn or damaged parts as needed to prevent further damage to the motor.
  2. Inspect the motor’s air vents and cooling system to ensure proper airflow and prevent overheating. Clean the vents and surrounding area to remove any debris that may be blocking airflow.
  3. Lubricate the motor bearings and other moving parts as recommended by the manufacturer to ensure smooth operation and prevent wear and tear.
  4. Inspect the motor’s electrical connections and wiring for signs of damage or wear, including frayed wires or loose connections. Repair or replace any damaged components as needed to prevent electrical issues.
  5. Monitor the motor’s operating temperature to ensure it is within the recommended range. If the temperature is too high, check the cooling system and airflow to identify and correct any issues.
  6. Check and adjust the motor’s alignment as needed to prevent undue stress on the motor’s bearings and other components.
  7. Clean the motor and surrounding area clean and free of debris to prevent damage or overheating.
  8. Conduct regular performance testing to ensure the motor is operating at peak performance and identify any potential issues before they become larger problems.
  9. Regularly inspect the motor’s brushes and commutator for signs of wear or damage. Replace any worn or damaged parts as needed to prevent further damage to the motor.
  10. Motor megger testing is a diagnostic technique that uses a megohmmeter (megger) to measure the insulation resistance of motor windings to identify potential electrical faults or insulation deterioration.
  11. Motor winding resistance testing is a procedure used to measure the electrical resistance of the windings in an electric motor. It involves applying a known voltage to the windings and measuring the resulting current. By analyzing the resistance values, technicians can assess the condition of the motor, detect faults or short circuits, and ensure proper functionality.
  12. DC step voltage testing is a method used to assess the integrity of insulation in electrical equipment by applying a series of increasing voltage steps and measuring the resulting leakage current to detect potential insulation weaknesses or faults.
  13. Hi-pot testing, also known as dielectric withstand testing, is a procedure that assesses the ability of electrical equipment to withstand high voltage by applying a significantly higher voltage than the normal operating voltage to the equipment to check for insulation breakdown or faults.

Other Services Includes